| Battery Type |
AA |
| Battery Life |
250 hours |
| Temperature |
Operating Temperature |
-10 to 50 degree Celsius |
| Storage Temperature |
-40 to 60 degree Celsius |
| Temperature Co-efficient |
0.1 X (specified accuracy)/degree Celsius (< 18 degree Celsius or > 28 degree Celsius) |
| Relative Humidity |
0 percent to 90 percent (0 to 35 degree Celsius) 0 to 75 percent (35 to 40 degree Celsius) 0 to 45 percent (40 to 50degree Celsius) |
| Altitude |
Operating |
2000 metre |
| Storage |
12000 metre |
| Maximum Voltage Between Any Terminal and Earth Ground |
1000 V DC or AC RMS |
| Ω Fuse Protection From A Inputs |
0.44 Amps (44/100 Amps, 440 mA), 1000 volt FAST Fuse, Fluke specified part only |
| Display (LCD) |
Update rate |
4 per seconds |
| Volts, amps, ohms |
6000 counts |
| Frequency |
10000 counts |
| Capacitance |
1000 counts |
| minimum/Maximum Recording Accuracy |
| DC Functions |
± 12 counts for changes > 350 mS in duration |
| AC Functions |
± 40 counts for changes > 900 mS in duration |
| Input Characteristics |
 |
Overload Protection |
1100 volt RMS |
| Input Impedance (nominal) |
> 10 MΩ < 100 pF |
Common Mode Rejection Ratio (1 kΩ unbalance) |
> 120 dB at DC, 50 Hz or 60 Hz |
| Normal Mode Rejection |
> 60 dB at 50 Hz or 60 Hz |
 |
Overload Protection |
1100 volt RMS |
| Input Impedance (Nominal) |
> 10 MΩ < 100 pF |
Common Mode Rejection Ratio (1 kΩ unbalance) |
> 60 dB, DC to 60 Hz |
| Normal Mode Rejection |
> 60 dB at 50 Hz or 60 Hz |
 |
Overload Protection |
1100 volt RMS |
| Input Impedance (nominal) |
> 10 MΩ < 100 pF |
Common Mode Rejection Ratio (1 kΩ unbalance) |
> 120 dB at DC, 50 Hz or 60 Hz |
| Normal Mode Rejection |
> 60 dB at 50 Hz or 60 Hz |
| Open Circuit Test Voltage |
 |
Overload Protection |
1100 volt RMS |
| Input Impedance (nominal) |
< 2.7 volt DC |
Full Scale Voltage to 6 MΩ Full Scale Voltage 50 MΩ |
< 0.7 volt DC < 0.9 volt DC |
| Typical Short Circuit Current |
< 350 mA |
 |
Overload Protection |
1100 volt RMS |
| Input Impedance (nominal) |
< 2.7 volt DC |
Full Scale Voltage to 6 MΩ Full Scale Voltage 50 MΩ |
2.000 volt DC |
| Typical Short Circuit Current |
< 1.1 mA |
| AC Voltage |
| Range/Resolution |
|
600.0/0.1 mV 6.000/0.001 volt 60.00/0.01 volt 600.0/ 0.1 volt 1000/1 volt |
| Accuracy |
45 Hz to 500 Hz |
1.0 percent + 3 |
| 500 Hz to 1 kHz |
2.0 percent + 3 |
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance |
| mV |
Range/Resolution |
600.0/0.1 mV |
| Accuracy |
0.09 percent + 2 |
| V |
Range/Resolution |
6.000/ 0.001 volt 60.00/0.01 volt 600.0/0.1 volt 1000/ 1 volt |
| Accuracy |
0.09 percent + 2 0.15 percent + 2 |
| ))) |
Range/Resolution |
600/1 Ω |
| Accuracy |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer |
| Ω |
Range/Resolution |
600.0/0.1 Ω 6.000/0.001 kΩ 60.00/0.01 kΩ 60.00/0.1 kΩ 600.0/0.001 MΩ 50.00/0.01 MΩ |
| Accuracy |
0.5 percent + 2 0.5 percent + 1 1.5 percent + 3 |
| Diode test |
Range/Resolution |
2.000/0.001 volt |
| Accuracy |
1 percent + 2 |
| µF |
Range/Resolution |
1000/1 nF 10.00/0.01 μF 100.0/0.1 μF 9999 μF1 / 1 μF |
| Accuracy |
1.2 percent + 2 10 percent typical |
| AC and DC Current |
mA AC (45 Hz to 1 kHz) |
Range/Resolution |
60.00/0.01 mA 400.0 mA3 / 0.1 mA |
| Accuracy |
1.5 percent + 3 |
| mA DC |
Range/Resolution |
60.00/0.01 mA 400.0/0.1 mA |
| Accuracy |
0.5 percent + 3 |
| Frequency |
| Range/Resolution |
99.99/0.01 Hz 999.9/0.1 Hz 9.999/0.001 kHz 99.99/0.01 kHz |
| Accuracy |
0.1 percent + 1 |
| Size |
47.5 x 93 x 207 mm |
| Weight |
340 g |