Battery Type | AA Alkaline |
Battery Life | 100 hours minimum, 200 hours in logging mode |
Temperature | Operating | -20 to 55 degree Celsius |
Storage | -40 to 60 degree Celsius |
Relative Humidity | 0 to 90 percent (0 t0 37 degree Celsius), 0 to 65 percent (37 to 45 degree Celsius), 0 to 45 percent (45 to 55 degree Celsius) |
True-RMS AC Bandwidth | 100 kHz |
DC mV Resolution | 1 µV |
Megohm Range | Up to 500 MO |
Conductance | 50.00 nS |
Logging Memory | Up to 15000 Readings |
Maximum Voltage Between Any Terminal and Earth Ground | 1000 volt |
DC Volts | Range/Resolution | 50.000 mV, 500.00 mV, 5.0000, 50.000, 500.00, 1000.0 volt |
Basic Accuracy | 0.025 percent |
AC Volts | Range/Resolution | 50.000 mV, 500.00 mV, 5.0000, 50.000, 500.00, 1000.0 volt |
Basic Accuracy | 0.4 percent (True-RMS) |
DC Current | Range/Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000, 10.000 Amps |
Basic Accuracy | 0.05 percent |
AC Current | Range/Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000, 10.000 Amps |
Basic Accuracy | 0.6 percent (True-RMS) |
Temperature (Excluding Probe) | Range/Resolution | -200 to 1350 degree Celsius |
Basic Accuracy | 1.0 percent |
Resistance | Range/Resolution | 500.00 O, 5.0000, 50.000, 500.00 kO, 5.0000, 50.00, 500.0 MO |
Basic Accuracy | 0.05 percent |
Capacitance | Range/Resolution | 1.000 n, 10.00, 100.0 nF, 1.000, 10.00, 100.0, 1000 µF, 10.00, 100 mF |
Basic Accuracy | 1.0 percent |
Frequency | Range/Resolution | 99.999, 999.99 Hz, 9.9999, 99.999, 999.99 kHz |
Basic Accuracy | 0.005 percent |
Connectivity | Optional infrared connector via Fluke ir3000 FC |
Size | 222 x 102 x 60 mm |
Weight | 0.87 kg |