Fluke 1550C Insulation Resistance Tester Kit
The Fluke 1550C insulation resistance testing kit offers digital insulation testing up to 5 kV. And with the Fluke Connect wireless app, you can perform tests and collect data from a safe distance. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values. And you can create reports quickly, simply using drag-and-drop-something you won’t find anywhere else.
Features:
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 volt AC or DC for increased user safety
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user-defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Timer settings up to 99 minutes for timed tests
- Real-time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
Specifications:
| Battery Type |
12 volt Lead-Acid Rechargeable Battery |
| Charger Input (AC) |
85 to 250 volt AC 50/60 Hz 20 VA |
| Operating Temperature |
-20 to 50 degree Celsius |
| Storage Temperature |
-20 to 65 degree Celsius |
| Humidity |
80 percent to 31 degree Celsius decreasing linearly to 50 percent at 50 degree Celsius |
| Altitude |
2000 metre |
| Enclosure Sealing |
IP40 |
| Input Overload Protection |
1000 volt AC |
| Test Voltage (DC) |
| 250 volt |
Range |
< 250 kΩ, 250 to 5 GΩ 5 to 50 GΩ > 50 GΩ |
| Accuracy (± Reading) |
Unspecified 5 percent 20 percent Unspecified |
| 500 volt |
Range |
< 500 kΩ 500 to 10 GΩ 10 to 100 GΩ > 100 GΩ |
| Accuracy (± Reading) |
Unspecified 5 percent 20 percent Unspecified |
| 1000 volt |
Range |
< 1 MΩ 1 to 20 GΩ 20 to 200 GΩ > 200 GΩ |
| Accuracy (± Reading) |
Unspecified 5 percent 20 percent Unspecified |
| 2500 volt |
Range |
< 2.5 MΩ 2.5 to 50 GΩ 50 to 500 GΩ > 500 GΩ |
| Accuracy (± Reading) |
Unspecified 5 percent 20 percent Unspecified |
| 5000 volt |
Range |
< 5 MΩ 5 to 100 GΩ 100 to 1 TΩ > 1 TΩ |
| Accuracy (± Reading) |
Unspecified 5 percent 20 percent Unspecified |
| Bar Graph Range |
0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) |
| Insulation Test Voltage Accuracy |
-0 percent, +10 percent at 1 mA load current |
| Induced AC Mains Current Rejection |
2 mA Maximum |
| Charging Rate for Capacitive Load |
5 seconds per μF |
| Discharge Rate for Capacitive Load |
1.5 s/μF |
| Leakage Current Measurement |
Range |
1 nA to 2 mA |
| Accuracy |
±(5 percent + 2 nA) |
| Capacitance Measurement |
Range |
0.01 to 15.00 μF |
| Accuracy |
±(15 percent rdg + 0.03 μF) |
| Timer |
Range |
0 to 99 minutes |
| Resolution Setting |
1 minute |
| Resolution Indication |
1 second |
| Live Circuit Warning |
Warning Range |
30 to 660 volt AC/DC, 50/60 Hz |
| Voltage Accuracy |
±(15 percent + 2 V) |
| Size |
269 x 277 x 160 mm |
| Weight |
3.7 kg |
Includes:
- Test Cables with Alligator Clips (Red, Black, Green)
- Infrared Adapter with Interface Cable
- FlukeView Forms Basic CD-ROM
- AC Power Cord
- Certificate of Calibration
- English manual
- User Manual on CD-ROM
- Quick Reference Card
- Software License Agreement
- Registration Card
- FlukeView Forms Installation Guide
- USB-IR Cable Installation Guide
- Heavy-Duty Alligator Clip Leads
- Hard Case