Battery Voltage | 9 volt |
Battery Type | Alkaline |
Battery Life | 300 hours Typical, without Backlight |
Maximum Voltage between Any Terminal and Earth Ground | 600 volt |
Display | 3 3/4-digits, 6000 counts, updates 4/second |
Operating Temperature | -10 to 50 degree Celsius |
Storage Temperature | -40 to 60 degree Celsius |
Temperature Co-Efficient | 0.1 x (Specified Accuracy) / Celsius (< 18 degree Celsius or > 28 degree Celsius) |
Operating Altitude | 2000 metre |
Storage Altitude | 10000 metre |
Relative Humidity | 95 percent to 30 degree Celsius 75 percent to 40 degree Celsius 45 percent to 50 degree Celsius |
VCHEK1 2 3 | Range | 6.000/60.00/600.0 volt |
Resolution | 0.001/0.01/0.1 volt |
Accuracy | DC, 45 to 500 Hz: 2.0 percent + 3 500 Hz to 1 kHz: 4.0 percent + 3 |
Diode Test4 | Range | 2.000 volt |
Resolution | 0.001 volt |
Accuracy | 2.0 percent + 3 |
Continuity4 | Accuracy | Beeper on < 20 O, off > 250 O detects opens or shorts of 500 µs or longer |
O4 | Range | 600.0 O/6.000 kO/60.00 kO |
Resolution | 0.1 O/0.001 kO/0.01 kO |
Accuracy | 0.9 percent + 2 / 0.9 percent + 1 / 0.9 percent + 1 |
Capacitance4 | Range | 1000 nF/10.00 µF/100.0 µF/9999 µF |
Resolution | 1 nF/0.01 µF/0.1 µF/ 1 µF |
Accuracy | 1.9 percent + 2 100 µF - 1000 µF: 1.9 percent + 2 1000 µF: 5 percent + 20 |
Vibration | Per MIL-PRF-28800 for Class 2 Instrument |
VCHEK | Input Impedance (Nominal) | ~3 kO < 300 pF |
VCHEK | Common Mode Rejection Ratio (1 kO unbalanced) | > 60 dB at DC, 50 or 60 Hz |
O | Open Circuit Test Voltage | < 2.7 VDC |
Full Scale Voltage | < 0.7 VDC |
Diode Test | Open Circuit Test Voltage | 2.7 VDC |
Full Scale Voltage | 2.000 VDC |
O | Short Circuit Current | < 350 µA |
Diode Test | Short Circuit Current | < 1.0 mA |
Size (H x W x L) | 167.1 x 85.1 x 46.0 mm |
Weight | 0.404 kg |