FLUKE 1732 Advanced Three-Phase Electrical Energy Logger

€3,440.31 - €4,296.39 Inc. VAT

Code Description Type No. Quantity Price Inc. VAT
E10659 Energy Logger 1732 EUS €4,296.39
E10660 Energy Logger Basic 1732 B €3,440.31
Add to Basket
Delivery Info

Please allow 1 - 2 Business Days for Delivery

Free delivery on all orders over €49.99 + VAT, Click here for more information 

Returns Policy

Easy Returns via Store, Post or Courier

Caulfield Industrial  are happy to accept items returned to us within 28 days of purchase and in this case we offer you an exchange or a full refund once we receive the items and process them in our warehouse. Any returns which fall outside this 28 day time period may be considered on a case-by-case basis and is at the discretion of Caulfields and may be refunded as a credit against a future purchase. All items must be returned to Caulfields in the same condition in which they were shipped and in a saleable condition. Caulfield Industrial reserves the right to refuse a return if it is determined that the item has been used or worn and then returned for any reason other than being ‘faulty’.

Downloads
Click to view complete product details

Fluke 1732 Advanced Three-Phase Electrical Energy Logger

 

The Fluke 1732 Three-Phase Electrical Energy loggers introduce a new simplicity to discovering sources of electrical energy waste. Discover when and where energy in your facility is being consumed, from the service entrance to individual circuits. Access and share data remotely with your team via the Fluke Connect app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits, and check-ins. Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.

Features:
  • Automatically capture and log voltage, current, power, power factor, energy, and associated values
  • View data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities’ WiFi infrastructure
  • Power instrument directly from the measured circuit
  • 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
  • With included 3 flexible current probes
  • More than 20 separate logging sessions can be stored on the instruments
  • All measured values are automatically logged so you never lose measurement trends
  • Quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
  • Perform convenient in-the-field analysis and data checks with the full graphical display
  • Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function
  • No need to return to the workshop for download and setup or to take a computer to the electrical panel
  • Download and analyze every detail of energy consumption with our automated reporting
Specifications:
Battery Type Lithium-Ion
Battery Life 4 hours in standard operating mode, up to 5.5 hours in power saving mode
Power Supply
Voltage Range 100 to 500 volt using safety plug input when powering from the measurement circuit
100 to 240 volt using a standard power cord (IEC 60320 C7)
Power Consumption Maximum 50 VA (maximum 15 VA when powered using IEC 60320 input)
Efficiency ≥ 68.2 percent (in accordance with energy efficiency regulations)
Maximum No-Load Consumption < 0.3 watt only when powered using IEC 60320 input
Mains Power Frequency 50/60 Hz ±15 percent
Resolution 16-bit Synchronous Sampling
Sampling Frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input Signal Frequency 50/60 Hz (42.5 to 69 Hz)
Circuit Types 1-φ, 1-φ IT, Split-phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)
Data Storage Internal Flash Memory (not user replaceable)
Memory Size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events
Basic Interval
Measured Parameters Voltage, Current, Aux, Frequency, THD V, THD A, Power, Power Factor, Fundamental Power, DPF, Energy
Averaging Interval User selectable: 1, 5, 10, 30 seconds, 1, 5, 10, 15, 30 minutes
Averaging Time Minimum/Maximum Values Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200 ms
Demand Interval (Energy Meter Mode)
Measured Parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval User selectable: 5, 10, 15, 20, 30 minutes, off
Interfaces
USB-A File transfer via USB flash drive, firmware updates
Max. current: 120 mA
Wi-Fi File transfer and remote control via direct connection or Wi-Fi infrastructure
Bluetooth Read auxiliary measurement data from Fluke Connect 3000 series modules (requires 1734, or 1732 upgrade option)
USB-Mini Data Download Device to PC
Voltage Inputs
Number of inputs 4 (3 phases and neutral)
Maximum Input Voltage 1000 Vrms, CF 1.7
Input impedance 10 MΩ
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and Variable
Measurement Category 1000 V CAT III/600 V CAT IV
Current Inputs
Number of Inputs 3, mode selected automatically for attached sensor
Input Voltage Clamp input: 500/50 mVrms; CF 2.8
Rogowski Coil input 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range 1 to 150 Amps/10 to 1500 Amps with thin flexible current probe i17XX-flex1500 12"
3 to 300 Amps/30 to 3000 Amps with thin flexible current probe i17XX-flex3000 24"
6 to 600 Amps/60 to 6000 Amps with thin flexible current probe i17XX-flex6000 36"
40 mA to 4 Amps/0.4 to 40 Amps with 40 Amps clamp i40s-EL
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and Variable
Auxiliary Inputs
Number of inputs 2
Input Range 0 to ±10 V dc, 1reading/s
Scale Factor (available 2014) Format: mx + b (gain and offset) user configurable
Displayed Units (available 2014) User Configurable (7 characters, for example, degree Celsius, psi, or m/s)
Wireless Connection
Number of Inputs 2
Supported Modules Fluke Connect 3000 series
Acquisition 1 Reading/seconds
Environmental Specifications
Operating Temperature -10 to 50 degree Celsius
Storage Temperature -20 to 60 degree Celsius, with battery: -20 to 50 degree Celsius
Operating Humidity 10 to 30 degree Celsius, maximum 95 percent RH
30 to 40 degree Celsius, maximum 75 percent RH
40 to 50 degree Celsius, maximum 45 percent RH
Operating Altitude 2000 metre (up to 4000 metre derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage Altitude 12000 metre
Temperature Coefficient 0.1 x accuracy specification/°C
Colour LCD Display 4.3" active matrix TFT, 480 x 272 pixels, resistive touch panel
Accuracy
Parameter Range Resolution Intrinsic Accuracy at Reference Conditions (percent of Reading + percent of Full Scale)
Voltage 1000 volt 0.1 volt ±(0.2 percent + 0.01 percent)
Current: Direct Input i17xx-flex 1500 12" 150 Amps 0.1 Amps ±(1 percent + 0.02 percent)
1500 Amps 1 Amps ±(1 percent + 0.02 percent)
i17xx-flex 3000 24" 300 Amps 1 Amps ±(1 percent + 0.03 percent)
3000 Amps 10 Amps ±(1 percent + 0.03 percent)
i17xx-flex 6000 36" 600 Amps 1 Amps ±(1.5 percent + 0.03 percent)
6000 Amps 10 Amps ±(1.5 percent + 0.03 percent)
i40s-EL clamp 4 Amps 1 mA ±(0.7 percent + 0.02 percent)
40 Amps 10 mA ±(0.7 percent + 0.02 percent)
Frequency 42.5 to 69 Hz 0.01 Hz ±(0.1 percent)
Auxillary Input ±10 volt DC 0.1 mV ±(0.2 percent + 0.02 percent)
Voltage Minimum/Maximum 1000 volt 0.1 volt ±(1 percent + 0.1 percent)
Current Minimum/Maximum Defined by accessory Defined by accessory ±(5 percent + 0.2 percent)
THD on Voltage 1000 percent 0.1 percent ±0.5
THD on Current 1000 percent 0.1 percent ±0.5
Intrinsic Uncertainty ±(percent of reading + percent of range)
Parameter Influence quantity iFlex1500-12 iFlex3000-24 iFlex6000-36 i40S-EL
150/1500 Amps 300/3000 Amps 600/6000 Amps 4/40 Amps
Active Power P PF ≥ 0.99 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Active Energy Ea PF ≥ 0.99 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Apparent power S 0 ≤ PF ≤ 1 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Apparent Energy Eap 0 ≤ PF ≤ 1 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Reactive Power Q 0 ≤ PF ≤ 1 2.5 percent of measured apparent power
Reactive Energy Er 0 ≤ PF ≤ 1 2.5 percent of measured apparent power
Power Factor PF   ±0.025
Displacement Power Factor   ±0.025
DBF/cos?   ±0.025
Additional uncertainty in percent of Range¹ VP-N>250 volt 0.015 percent 0.0225 percent 0.0225 percent 0.015 percent
Size Instrument: 198 x 167 x 55 mm
Power supply: 130 x 130 x 45 mm
An instrument with Power Supply Attached: 198 x 167 x 90 mm
Weight Instrument: 1.1 kg
Power supply: 0.4 kg
1732 EUS Energy Logger Includes:
  • Fluke 1732/EUS Instrument
  • Flexible Current Probe
  • Power Supply
  • Voltage Test Leads
  • Alligator Clips
  • Energy Analyze Plus Software
  • Line Cords
  • Colour Coding Set
  • Documentation on USB Flash Drive
  • Soft Case
1732 B Energy Logger Basic:
  • Fluke 1732/B Instrument
  • Voltage Test Leads
  • Alligator Clips
  • Energy Analyze Plus Software
  • Line Cords
  • Colour Coding Set
  • Documentation on USB Flash Drive
  • Soft Case

Technical File: