Fluke 1662 Multifunction Installation Tester

The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test and self-test save time and give you more confidence in your results.

Features:
  • Measures RCD switching time and tripping level (ramp test)
  • Measures trip time and current for RCD type Amps and AC in one test
  • Measures RCD variable current
  • Provides automatic RCD test sequence
  • Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
  • Provides unique zero adapters for fast, reliable and accurate test lead and mains cord compensation
  • Includes a phase sequence indicator
  • Checks wiring polarity to detect broken N wires
  • Measures insulation resistance and loop and line resistance
  • Measures motor windings with the continuity test
Includes:
  • 6 x AA Batteries
  • Zero Adapter
  • Heavy Duty Main Cord
  • STD Standard Test Lead Set
  • Padded Carrying and Waist Strap
  • Remote Control Probe and Lead
  • User Manual on CD-ROM
  • Quick Reference Guide
  • Hard Carrying Case
Delivery Info

Please allow 1 - 2 Business Days for Delivery

Free delivery on all orders over €49.99 + VAT, Click here for more information 

Returns Policy

Easy Returns via Store, Post or Courier

Caulfield Industrial  are happy to accept items returned to us within 28 days of purchase and in this case we offer you an exchange or a full refund once we receive the items and process them in our warehouse. Any returns which fall outside this 28 day time period may be considered on a case-by-case basis and is at the discretion of Caulfields and may be refunded as a credit against a future purchase. All items must be returned to Caulfields in the same condition in which they were shipped and in a saleable condition. Caulfield Industrial reserves the right to refuse a return if it is determined that the item has been used or worn and then returned for any reason other than being ‘faulty’.

Click to view complete product details


Specifications:
Battery TypeAA
AC Voltage Measurement
Range500 volt
Resolution0.1 volt
Accuracy 45-66 Hz0.8 percent + 3
Input Impedance360 kΩ
Overload Protection660 volt RMS
Continuity Testing (RLO)
Range (Autoranging)20/200/2000 Ω
Resolution0.01/0.1/1 Ω
Open Circuit Voltage>4 volt
Insulation Resistance Measurement (RISO)
Test Voltages50, 100, 250, 500, 1000 volt
The accuracy of Test Voltage (at rated test current)+10 percent, -0 percent
Test Voltage50 volt
100 volt
250 volt
500 volt
1000 volt
Insulation resistance range20/50 MΩ
20/100 MΩ
20/200 MΩ
20/200/500 MΩ
20/200/1000 MΩ
Resolution0.01/0.1 MΩ
0.01/0.1 MΩ
0.01/0.1 MΩ
0.01/0.1/1 MΩ
0.01/0.1/1 MΩ
Test Current1 mA at 50 kΩ
1 mA at 100 kΩ
1 mA at 250 kΩ
1 mA at 500 kΩ
1 mA at 1 MΩ
Loop and Line Impedance (ZI)
Range10/0.001 Ω/High Current mΩ Mode
Resolution0.01/0.1/1 Ω
Prospective earth fault current, PSC test
Range1000 Amps/10 kA (50 kA)
Resolution1 Amps/0.1 kA
ComputationProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD Testing, RCD Types Tested
RCD TypeAC¹
G²,S³
Model 1663A4, AC¹, G²,S³
NotesResponds to AC
General, no delay
Time delay
Responds to pulsed signal
Responds to smooth DC signal
Tripping speed test (ΔT)
Current settings¹10, 30, 100, 300, 500, 1000 mA – VAR
10-30-100 mA
Multiplierx ½, x 1
x 5
Measurement RangeRCD Type G310 ms
50 ms
RCD Type S510 ms
160 ms
Notes1000 mA Type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current Range30 percent to 110 percent of RCD Rated Current
Step Size10 percent of IΔN²
Dwell TimeType G300 ms/step
Type S500 ms/step
Measurement Accuracy±5%
Specified Trip Current Ranges (EN 61008-1)50 to 100 percent for Type AC
35 to 140 percent for Type A (>10 mA)
35 to 200 percent for Type A (≤10 mA)
50 to 200 percent for Type B
Notes30 to 150 percent for Type A IΔN > 10 mA
30 to 210 percent for Type A IΔN = 10 mA
20 to 210 percent for Type B
Earth Resistance Test (RE)
Range200/2000 Ω
Resolution0.1/1Ω
Frequency128 Hz
Output Voltage25 volt
Phase Sequence Indication
Icon Phase Sequence Indicator is Active.
Size100 x 250 x 125 mm
Weight1.3 Kg