Battery Type | Alkaline |
Battery Life | 400 hours |
Maximum Voltage Between Any Terminal and Earth Ground | 600 volt |
Operating Temperature | -10 to 50 degree Celsius |
Storage Temperature | -40 to 60 degree Celsius |
Display | Digital: 6000 counts, updates 4 per seconds |
Bar Graph | 33 segments, updates 32 per seconds |
DC Millivolts | Range/resolution | 600.0/0.1 mV |
Accuracy | ± ([percent of reading] + [counts]): 0.5 percent + 2 |
DC Volts | Range/Resolution | 6.000/0.001 volt 60.00/0.01 volt 600.00/0.1 volt |
Accuracy | ± ([percent of reading] + [counts]): 0.5 percent + 2 |
AC Millivolts True-RMS | Range/Resolution | 600.0/0.1 mV |
Accuracy | 1.0 percent + 3 (DC, 45 Hz to 500 Hz) 2.0 percent + 3 (500 Hz to 1 kHz) |
AC Volts True-RMS | Range/Resolution | 6.000/0.001 volt 60.00/0.01 volt 600.0/0.1 volt |
Accuracy | 1.0 percent + 3 (DC, 45 Hz to 500 Hz) 2.0 percent + 3 (500 Hz to 1 kHz) |
Continuity | Range/Resolution | 600/1 O |
Accuracy | Beeper on < 20 O, off > 250 O detects opens or shorts of 500 µs or longer. |
Ohms | Range/Resolution | 600.0/0.1 O 6.000/0.001 kO 60.00/0.01 kO 600.0/0.1 kO 6.000/0.001 MO |
Accuracy | 0.9 percent + 1 |
Range/Resolution | 40.00/0.01 MO |
Accuracy | 5 percent + 2 |
Diode Test | Range/Resolution | 2.00/0.001 volt |
Accuracy | 0.9 percent + 2 |
Capacitance | Range/Resolution | 1000/1 nF 10.00/0.01 µF 100.0/0.1 µF 9999/1 µF 100 µF to 1000 µF |
Accuracy | 1.9 percent + 2 |
Range/Resolution | > 1000 µF |
Accuracy | 5 percent + 20 percent |
Lo-Z Capacitance | Range | 1 nF to 500 µF |
Accuracy | 10 percent + 2 typical |
AC Amps True-RMS (45 Hz to 500Hz) | Range/Resolution | 6.000/0.001 Amps 10.00/0.01 Amps |
Accuracy | 1.5 percent + 3 20 A overload for 30 seconds maximum |
DC Amps | Range/Resolution | 6.000/0.001 Amps 10.00/0.01 Amps |
Accuracy | 1.0 percent + 3 20 A overload for 30 seconds maximum |
Hz (Volt or Amps Input) | Range/Resolution | 99.99/0.01 Hz 999.9/0.01 Hz 9.999/ 0.001 kHz 50/ 0.01 kHz |
Accuracy | 0.1 percent + 2 |
Size | 167 x 84 x 46 mm |
Weight | 0.55 kg |