FLUKE 115 True-RMS Digital Multimeter

€279.00 Ex. VAT

Code C11002


Add to Basket
Product Details

Fluke 115 True-RMS Digital Multimeter

The Fluke 115 is the compact, general purpose troubleshooting tool for field service technicians and general purpose electrical and electronic test requirements, the Fluke 115 True -RMS digital multimeter provides the perfect answer. Its simple, one-handed operation and compact design meet the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency, and capacitance for quick verifications.

Features:
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Minimum, Maximum and Average with elapsed time to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features a compact ergonomic design for one-handed operation
  • Fits into optional ToolPak magnetic hanger for hands-free operation
  • Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V environments
Includes:
  • 9-volt Batteries
  • Holster
  • Silicone Test Lead Set
  • User Manual

Like anything supplied by Caulfield Industrial, you are guaranteed only the highest quality with this multimeter. Our rapid delivery system ensures that you will have your order within days of purchasing it.

Maximize your proficiency by getting yourself a Fluke digital multimeter from Caulfield Industrial.

Delivery Info

Please allow 1 - 2 Business Days for Delivery

Free delivery on all orders over €49.99 + VAT, Click here for more information 

Returns Policy

Easy Returns via Store, Post or Courier

Caulfield Industrial  are happy to accept items returned to us within 28 days of purchase and in this case we offer you an exchange or a full refund once we receive the items and process them in our warehouse. Any returns which fall outside this 28 day time period may be considered on a case-by-case basis and is at the discretion of Caulfields and may be refunded as a credit against a future purchase. All items must be returned to Caulfields in the same condition in which they were shipped and in a saleable condition. Caulfield Industrial reserves the right to refuse a return if it is determined that the item has been used or worn and then returned for any reason other than being ‘faulty’.

Downloads
Click to view complete product details


Specifications:
Battery TypeAlkaline
Battery Life400 hours
Maximum Voltage Between Any Terminal and Earth Ground600 volt
Operating Temperature-10 to 50 degree Celsius
Storage Temperature-40 to 60 degree Celsius
DisplayDigital: 6000 counts, updates 4 per seconds
Bar Graph33 segments, updates 32 per seconds
DC MillivoltsRange/resolution600.0/0.1 mV
Accuracy± ([percent of reading] + [counts]): 0.5 percent + 2
DC VoltsRange/Resolution6.000/0.001 volt
60.00/0.01 volt
600.00/0.1 volt
Accuracy± ([percent of reading] + [counts]): 0.5 percent + 2
AC Millivolts True-RMSRange/Resolution600.0/0.1 mV
Accuracy1.0 percent + 3 (DC, 45 Hz to 500 Hz)
2.0 percent + 3 (500 Hz to 1 kHz)
AC Volts True-RMSRange/Resolution6.000/0.001 volt
60.00/0.01 volt
600.0/0.1 volt
Accuracy1.0 percent + 3 (DC, 45 Hz to 500 Hz)
2.0 percent + 3 (500 Hz to 1 kHz)
ContinuityRange/Resolution600/1 O
AccuracyBeeper on < 20 O, off > 250 O detects opens or shorts of
500 µs or longer.
OhmsRange/Resolution600.0/0.1 O
6.000/0.001 kO
60.00/0.01 kO
600.0/0.1 kO
6.000/0.001 MO
Accuracy0.9 percent + 1
Range/Resolution40.00/0.01 MO
Accuracy5 percent + 2
Diode TestRange/Resolution2.00/0.001 volt
Accuracy0.9 percent + 2
CapacitanceRange/Resolution1000/1 nF
10.00/0.01 µF
100.0/0.1 µF
9999/1 µF
100 µF to 1000 µF
Accuracy1.9 percent + 2
Range/Resolution> 1000 µF
Accuracy5 percent + 20 percent
Lo-Z CapacitanceRange1 nF to 500 µF
Accuracy10 percent + 2 typical
AC Amps True-RMS
(45 Hz to 500Hz)
Range/Resolution6.000/0.001 Amps
10.00/0.01 Amps
Accuracy1.5 percent + 3
20 A overload for 30 seconds maximum
DC AmpsRange/Resolution6.000/0.001 Amps
10.00/0.01 Amps
Accuracy1.0 percent + 3
20 A overload for 30 seconds maximum
Hz (Volt or Amps Input)Range/Resolution99.99/0.01 Hz
999.9/0.01 Hz
9.999/ 0.001 kHz
50/ 0.01 kHz
Accuracy0.1 percent + 2
Size167 x 84 x 46 mm
Weight0.55 kg