Fluke 54 II B Handheld Dual Input Data Logging Thermometer
Fluke 54 II B dual input digital thermometer can log up to 500 points of data to internal memory. Fast response and laboratory accuracy (0.05 percent + 0.3 degree Celsius). Take contact temperature for checking motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, and S type thermocouple (temperature sensors).
Features:
- Recall function allows logged data to be easily reviewed on the meter display
- Infrared USB communication port allows data to be exported to optional FlukeView forms temperature PC software for further analysis and graphing
- Data Logging up to 500 points of data with user adjustable recording interval
- Relative time clock on Minimum, Maximum, and Average provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, E, R, S, and N-type thermocouples
- Splash and dust resistant case protected by impact absorbing holster
- The user-friendly front panel is easy to set up and operate
- Sleep mode increases battery life
- Battery door allows easy battery replacement without breaking the calibration seal
- Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation
| Battery Type |
AA |
| Battery Life |
1000 hour life |
| Operating Temperature |
-10 to 50 degree Celsius |
| Storage Temperature |
-40 to 60 degree Celsius |
| Humidity (Without Condensation) |
0 to 90 percent; 0 to 35 degree Celsius |
| 0 to 70 percent; 0 to 50 degree Celsius |
| Temperature Accuracy |
Above -100 degree Celsius |
J, K, T, E, and N-Type: ±(0.05 percent + 0.3 degree Celsius) |
| R and S-Type: ±(0.05 percent + 0.4 degree Celsius) |
| Below -100 degree Celsius |
J, K, E, and N-Types: ±(0.20 percent + 0.3 degree Celsius) |
| T-Type: ±[0.50 percent + 0.3 degree Celsius] |
| Temperature |
J-Type |
-210 to 1200 degree Celsius |
| K-Type |
-200 to 1372 degree Celsius |
| T-Type |
-250 to 400 degree Celsius |
| E-Type |
-150 to 1000 degree Celsius |
| N-Type |
-200 to 1300 degree Celsius |
| R and S-Type |
0 to 1767 degree Celsius |
| Temperature Scale |
ITS-90 |
| Applicable Standards |
NIST-175 |
| Display Resolution |
0.1 degree Celsius, 0.1 Kelvin < 1000 |
| 1 degree Celsius, 1 Kelvin ≥ 1000 |
| Size |
173 x 86 x 38 mm |
| Weight |
0.4 kg |