Fluke 117 Non-Contact Voltage Electrician's Ideal Multimeter

Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Minimum, Maximum and Average readings, and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.

Features:
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features compact ergonomic design for one-handed operation
  • Fits into optional ToolPak magnetic hanger for hands-free operation
  • Safe use in CAT III 600 V environments
  • A large white LED backlight to improve measurement visibility in poorly lit areas
  • VoltAlert technology for fast, go/no go non-contact voltage detection
  • AutoVolt and low input impedance modes to provide faster, more accurate readings
Includes:
  • Silicone Test Lead Set
  • Holster
  • User Manual
Delivery Info

Please allow 1 - 2 Business Days for Delivery

Free delivery on all orders over €49.99 + VAT, Click here for more information 

Returns Policy

Easy Returns via Store, Post or Courier

Caulfield Industrial  are happy to accept items returned to us within 28 days of purchase and in this case we offer you an exchange or a full refund once we receive the items and process them in our warehouse. Any returns which fall outside this 28 day time period may be considered on a case-by-case basis and is at the discretion of Caulfields and may be refunded as a credit against a future purchase. All items must be returned to Caulfields in the same condition in which they were shipped and in a saleable condition. Caulfield Industrial reserves the right to refuse a return if it is determined that the item has been used or worn and then returned for any reason other than being ‘faulty’.

Downloads
Click to view complete product details


Specifications:
Battery TypeAlkaline
Battery Life400 hours
Maximum Voltage Between Any Terminal and Earth Ground600 volt
Operating Temperature-10 to 50 degree Celsius
Storage Temperature-40 to 60 degree Celsius
DisplayDigital: 6000 counts, updates 4 per seconds
Bar Graph33 segments, updates 32 per seconds
DC MillivoltsRange/Resolution600.0/0.1 mV
Accuracy±([percent of reading] + [counts]): 0.5 percent + 2
DC VoltsRange/Resolution6.000/0.001 volt
60.00/0.01 volt
600.00/0.1 volt
Accuracy±([percent of reading] + [counts]): 0.5 percent + 2
Auto VoltsRange/Resolution600.0/0.1 volt
Accuracy2.0 percent + 3 (DC, 45 Hz to 500 Hz)
4.0 percent + 3 (500 Hz to 1 kHz)
AC Millivolts True-RMSRange/Resolution600.0/0.1 mV
Accuracy1.0 percent + 3 (DC, 45 Hz to 500 Hz)
2.0 percent + 3 (500 Hz to 1 kHz)
AC Volts True-RMSRange/Resolution6.000/0.001 volt
60.00/0.01 volt
600.0/0.1 volt
Accuracy1.0 percent + 3 (DC, 45 Hz to 500 Hz)
2.0 percent + 3 (500 Hz to 1 kHz)
ContinuityRange/Resolution600/1 O
AccuracyBeeper on < 20 O, off > 250 O detects opens or shorts of
500 µs or longer
OhmsRange/Resolution600.0/0.1 O
6.000/0.001 kO
60.00/0.01 kO
600.0/0.1 kO
6.000/0.001 MO
Accuracy0.9 percent + 1
Range/Resolution40.00/0.01 MO
Accuracy5 percent + 2
Diode TestRange/Resolution2.00/0.001 volt
Accuracy0.9 percent + 2
CapacitanceRange/resolution1000/1 nF
10.00/0.01 µF
100.0/0.1 µF
999/1 µF
100 µF to 1000 µF
Accuracy1.9 percent + 2
Range/Resolution> 1000 µF
Accuracy5 percent + 20 percent
Lo-Z CapacitanceRange1 nF to 500 µF
Accuracy10 percent + 2 typical
AC Amps True-RMS (45 Hz to 500 Hz)Range/Resolution6.000/0.001 Amps
10.00/0.01 Amps
Accuracy1.5 percent + 3
20 Amps continuous overload for 30 seconds maximum
DC AmpsRange/Resolution

6.000/0.001 Amps, 10.00/0.01 Amps

Accuracy1.0 percent + 3
20 Amps continuous overload for 30 seconds maximum
Frequency (Volt or Amps Input)Range/Resolution99.99/0.01 Hz
999.99/0.1 Hz
9.999/0.001 Hz
50.00/0.01 Hz
Accuracy0.1 percent + 2
Weight0.55 kg