Fluke 355 True-RMS Clamp Meter available online - Caulfield Industrial
Go

Fluke 355 True-RMS Clamp Meter

€787.49 Ex Vat

€968.61 Inc VAT

Fluke 355 True-RMS Clamp Meter View Large Image
P-K10011

See Alternative
Title Quantity Price Availability
Fluke 355 True-RMS Clamp Meter €787.49 Ex Vat €968.61 Inc VAT
Add To Basket Add to Wishlist

Fluke 355 True-RMS Clamp Meter

 

Fluke confidently take reliable readings with the True RMS, Fluke 355 digital clamp meter the tool of choice for high current clamp-on amp meter measurement up to 2000 Amps. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

Features:
  • The large 58 mm jaw capacity is suitable for large or multiple conductors
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • Resistance to 400 K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the Minimum, Maximum and Average functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings
Specifications:
Battery Type AA
Battery Life (With Typical Usage, backlight off) 100 hours
Operating Temperature 0 to 50 degree Celsius
Storage Temperature -20 to 60 degree Celsius
Operating Humidity 0 to 95 percent (Non-Condensing)
Operating Altitude 2000 metre
Storage Altitude 10000 metre
Drop Test Requirements 1 metre
Temperature Coefficients Current 0.1 percent of reading per degree Celsius outside 22 to 24 degree Celsius
Voltage 0.1 percent of reading per degree Celsius outside 22 to 24 degree Celsius
Test Leads Rated to 1000 volt
Jaw Size 58 mm
Current Measurement DC and AC 10 to 100 Hz Range 40/400/2000 Amps, 1400 AC RMS
Resolution 10 mA/100 mA/ 1 Amps
Accuracy A: 1.5 percent rdg + 15 digits
A: 1.5 percent rdg + 5 digits
Trigger Level for Inrush 0.50/5.0/5 Amps
Trigger Level for Hz Filter Off 2.50/2.5/8 Amps
Trigger Level for Hz Filter On 0.50/2.5/8 Amps
Crest Factor (50/60 Hz) Range 40/400/2000 Amps, 1400 AC RMS
Crest Factor 2 at 33 Amps, 2.4 at 27 Amps
2 at 330 Amps, 2.4 at 270 Amps
2 at 1000 Amps, 2.4 at 833 Amps
Current Measurement AC 100.1 Hz to 1 kHz Range 40/400/2000 Amps, 1400 AC RMS
Resolution 10/100 mA/1 Amps
Accuracy 10 A: 3.5 percent rdg + 15 digits
10 A: 3.5 percent rdg + 5 digits
Trigger Level for Inrush 0.50/5.0/5 Amps
Trigger Level for Hz Filter Off 2.50/2.5/8 Amps
Trigger Level for Hz Filter On 0.50/2.5/8 Amps
Voltage Measurement DC and AC 10 Hz to 100 Hz
(600 volt and 1000 volt ranges have 10 percent over range to 660 volt and 1100 volt respectively)
Range 4/40/400/600 volt AC rms/1000 VDC
Resolution 1/10/100mV/ 1 volt
Accuracy 1 percent rdg + 10 digits
1 percent rdg + 5 digits
Trigger Level for Hz Filter Off 0.25/6 volt
Trigger Level for Hz Filter On 0.25/6 volt
Voltage Measurement AC 100.1 Hz to 1 kHz
(600 volt and 1000 volt ranges have 10 percent over range to 660 volt and 1100 volt respectively)
Range 4/40/400/600 volt AC RMS
Resolution 1/10/100/1 volt
Accuracy 3 percent rdg + 10 digits
3 percent rdg + 5 digits
Trigger Level for Hz Filter Off 0.050/0.25/ 6 volt
Trigger Level for Hz Filter On 0.050/0.25/6 volt
Ohms Measurement Range 4/40/400 kΩ
Resolution 0.1/1/10/100 Ω
Accuracy 1.5 percent + 5 digits
Continuity Beeper On at ≤ 30 Ω
Off at ≥ 100 Ω
Frequency Measurement Measurement Range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2 percent + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 percent + 5 counts
Trigger Level Refer to Current and Voltage Tables
Size 300 x 98 x 52 mm
Weight 0.814 kg
Includes:
  • 6 x AA Batteries
  • Silicone Rubber Test Leads
  • Test Probes
  • Alligator Clips
  • User Manual
  • Soft Carry Case

Clear All

Your Recently Viewed Products

Oops! Something went wrong there and we were unable to load the page you requested.

Sign Up